{"product_id":"artificiell-optisk-stralning-uv-ir-industri-2027","title":"Artificial optical radiation 2026\/2027 – UV, visible light \u0026 IR, risk assessment and action plan | Word\/PDF\/Excel","description":"\u003cp\u003eDocument the risks of artificial optical radiation from UV, visible, and infrared sources in industry. The template package helps employers, occupational health and safety managers, and occupational health and safety coordinators map sources, order exposure assessment reports, monitor control measures, and manage non-conformities in accordance with Swedish occupational health and safety law. It is a documentation aid, not a measurement method or a safety approval.\u003c\/p\u003e\n\u003cdiv style=\"border:1px solid #b7ccde;background:#f2f7fb;padding:16px;margin:16px 0;\"\u003e\n\n\u003ch2\u003ePackage Contents\u003c\/h2\u003e\n\n\u003cp\u003eVersion 1.0. Digital ZIP with 15 files: 7 editable DOCX files, 7 corresponding searchable PDFs, and 1 XLSX file. Five Swedish work templates, a Swedish guide, and an English guide to the Swedish documents.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #b7ccde;background:#f2f7fb;padding:16px;margin:16px 0;\"\u003e\n\n\u003ch2\u003eWhat the Files Contain\u003c\/h2\u003e\n\n\u003cp\u003eSource inventory, risk assessment, ordering of exposure assessment reports, action plan, and incident follow-up. The Excel file has nine tabs and 40 pre-formatted rows in each of the seven work registers.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\u003ch2\u003eWho Is the Package For?\u003c\/h2\u003e\u003cp\u003eWorkplaces where workers may be exposed to non-coherent optical radiation from, for example, industrial UV curing, optical inspection stations, or IR processes. Consider normal production, service, cleaning, and changes in work activities. Lasers, built-in laser systems, medical treatments, sunlight, and ionizing radiation are not included. Check other applicable occupational health and safety and equipment regulations separately.\u003c\/p\u003e\n\u003ch2\u003eDocument List\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse\"\u003e\n\n\u003cthead\u003e\u003ctr\u003e\n\n\u003cth scope=\"col\"\u003eDocument\u003c\/th\u003e\n\n\u003cth scope=\"col\"\u003eFormat\/Language\u003c\/th\u003e\n\n\u003cth scope=\"col\"\u003eUse\u003c\/th\u003e\n\n\n\u003c\/tr\u003e\u003c\/thead\u003e\n\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e01 Source Inventory\u003c\/td\u003e\n\n\u003ctd\u003eDOCX\/PDF, Swedish\u003c\/td\u003e\n\n\u003ctd\u003eEquipment, manufacturer information, work activities, and exposed groups\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e02 Risk Assessment\u003c\/td\u003e\n\n\u003ctd\u003eDOCX\/PDF, Swedish\u003c\/td\u003e\n\n\u003ctd\u003eExposure routes, simultaneous exposure, uncertainties, and need for investigation\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e03 Exposure Assessment Report\u003c\/td\u003e\n\n\u003ctd\u003eDOCX\/PDF, Swedish\u003c\/td\u003e\n\n\u003ctd\u003eOrdering and receipt control of a competent assessment\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e04 Action Plan\u003c\/td\u003e\n\n\u003ctd\u003eDOCX\/PDF, Swedish\u003c\/td\u003e\n\n\u003ctd\u003eTechnical and organizational measures, responsibilities, expiration date, protection, and verification evidence\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e05 Incident and Post-Control\u003c\/td\u003e\n\n\u003ctd\u003eDOCX\/PDF, Swedish\u003c\/td\u003e\n\n\u003ctd\u003eImmediate measures, medical examination when applicable, follow-up\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e06 Swedish User Guide\u003c\/td\u003e\n\n\u003ctd\u003eDOCX\/PDF, Swedish\u003c\/td\u003e\n\n\u003ctd\u003eWorkflow, legal sources, and examples\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e07 English User Guide\u003c\/td\u003e\n\n\u003ctd\u003eDOCX\/PDF, English\u003c\/td\u003e\n\n\u003ctd\u003eEnglish guidance to the Swedish documents\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e08 Control Register\u003c\/td\u003e\n\n\u003ctd\u003eXLSX, Swedish\u003c\/td\u003e\n\n\u003ctd\u003eNine tabs with control signals and follow-up\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\n\n\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eHow to Use the Templates\u003c\/h2\u003e\u003col\u003e\n\n\u003cli\u003eAssign each piece of equipment a source ID. Save the manufacturer's documentation and note the wavelength range, work activity, exposure time, and existing protection.\u003c\/li\u003e\n\n\u003cli\u003eAssess the cumulative exposure of the affected workers. Document direct eye and skin risks, indirect risks, sensitivity, and interaction with other sources.\u003c\/li\u003e\n\n\u003cli\u003eOrder a competent assessment when measurement or calculation is required. Record the report's method, conclusion, and limitations without replacing it with your own simplified calculation.\u003c\/li\u003e\n\n\u003cli\u003eDocument the action plan, responsibilities, expiration date, protection, and verification evidence. Follow up on training and control points.\u003c\/li\u003e\n\n\u003cli\u003eIn the event of an incident: follow safety and medical procedures, investigate the incident, and revise the risk assessment when necessary. Do not document medical diagnoses in the administrative register.\u003c\/li\u003e\n\n\n\u003c\/ol\u003e\n\u003ch2\u003eLegal Basis – AFS 2023:10, Chapter 12\u003c\/h2\u003e\u003cp\u003eThe provisions in Sections 4–7 address risk assessment, exposure limits, determination, and documentation of exposure. Annex 8 contains the limit values for non-coherent optical radiation. When exposure may exceed an applicable limit value, measurement or calculation is required. The register does not contain values from the annex or dose formulas; a competent assessor must use the correct method and assess combined sources.\u003c\/p\u003e\n\u003ch2\u003eAction Plan, Control, and Follow-up\u003c\/h2\u003e\u003cp\u003eAccording to Sections 8–10, the employer must manage risks with appropriate control measures and knowledge. If there is a risk of exceeding limits, an action plan is required. Signage and access restrictions are assessed according to Section 9. In the event of an exceedance, immediate risk reduction, root cause investigation, and preventive measures apply. Medical examination and follow-up are regulated in Sections 11–12. No template may be used to bypass protection or restart unsafe work.\u003c\/p\u003e\n\u003ch2\u003eExcel – Control and Action Register\u003c\/h2\u003e\u003cp\u003eTabs: Overview, Radiation Sources, Risks, Reports, Measures, Controls, Training, Incidents, and Sources. Input fields and status lists are separated from formula-based control signals. The workbook identifies, among other things, duplicate IDs, unknown source or risk references, missing information, and measures marked as verified without a date or evidence ID. Nine print areas, page width adjustment, and repeated register headers are pre-formatted. Control signals indicate administrative needs, not a safe workplace.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFictitious Example:\u003c\/strong\u003e UV source K-01 lacks a report for a changed work activity. Risk R-01 is registered as unclear. When the responsible person has ordered a competent investigation, the report can be linked to the risk. Measure A-01 cannot receive an administratively approved control signal if the verification date or evidence reference is missing. An actual safety assessment is performed separately.\u003c\/p\u003e\n\u003ch2\u003eFile Format and Language\u003c\/h2\u003e\u003cp\u003eUnzip the ZIP file. DOCX is editable, PDF is searchable and intended for reading and printing, not interactive forms. XLSX requires support for formulas and data validation. The work templates and Excel file are in Swedish; the English guide describes the workflow. The preview images show the actual documents and the workbook overview.\u003c\/p\u003e\n\u003ch2\u003eRelated Documents\u003c\/h2\u003e\u003cp\u003eFor chemical risks that may occur in the same process, \u003ca href=\"https:\/\/mallbutiken.se\/products\/kemiska-risker-riskbedomning-kemikalieforteckning-2026-2027\"\u003eChemical Risks – Risk Assessment and Chemical Inventory\u003c\/a\u003e is available. For systematic inspections, \u003ca href=\"https:\/\/mallbutiken.se\/products\/skyddsrond-arbetsmiljorond-2026-2027-checklista-riskbedomning-handlingsplan-word-pdf-excel\"\u003eSafety Inspection and Occupational Health and Safety Inspection\u003c\/a\u003e is available.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat Is Artificial Optical Radiation?\u003c\/h3\u003e\u003cp\u003eOptical radiation from sources other than the sun. The package focuses on non-coherent UV, visible light, and IR in industrial work activities.\u003c\/p\u003e\u003ch3\u003eWhat Types of Businesses Is the Package Suitable For?\u003c\/h3\u003e\u003cp\u003eWorkshops and industries with, for example, UV curing, optical inspection, or IR-based processes. Actual risk must be assessed on site.\u003c\/p\u003e\u003ch3\u003eWhat Regulations Apply?\u003c\/h3\u003e\u003cp\u003eAFS 2023:10, Chapter 12, Sections 4–12, and Annex 8 are central to the package's scope.\u003c\/p\u003e\u003ch3\u003eMust Every Light Source Be Measured?\u003c\/h3\u003e\u003cp\u003eNo, the employer must assess cumulative exposure. If limit values are at risk of being exceeded, measurement or calculation is required according to Section 6.\u003c\/p\u003e\u003ch3\u003eDoes Excel Calculate Exposure or Limit Values?\u003c\/h3\u003e\u003cp\u003eNo. The register documents reports and control signals. A competent assessor must determine the applicable values and cumulative exposure.\u003c\/p\u003e\u003ch3\u003eWhat Happens If a Report Is Missing?\u003c\/h3\u003e\u003cp\u003eDocument the gap and investigate further. Missing documentation is not evidence of safe exposure. Stop unsafe work.\u003c\/p\u003e\u003ch3\u003eWhat Should Be Done in the Event of an Exceedance?\u003c\/h3\u003e\u003cp\u003eReduce exposure immediately, investigate the cause, and prevent recurrence. Follow the requirements for medical examination and follow-up in Sections 11–12.\u003c\/p\u003e\u003ch3\u003eAre Lasers or IPL Treatments Included?\u003c\/h3\u003e\u003cp\u003eNo. Lasers, including built-in lasers, medical treatments, sunlight, and ionizing radiation are outside the product's scope.\u003c\/p\u003e\u003ch3\u003eDoes the Template Approve Protective Equipment and Barriers?\u003c\/h3\u003e\u003cp\u003eNo. It documents measures and actual evidence of control; the responsible employer and competent assessor must determine safety.\u003c\/p\u003e\u003ch3\u003eWhat Languages Are Included?\u003c\/h3\u003e\u003cp\u003eFive Swedish work templates, a Swedish guide, an English guide, and a Swedish Excel workbook.\u003c\/p\u003e\n\u003ch2\u003eLegal Sources\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.av.se\/arbetsmiljoarbete-och-inspektioner\/publikationer\/foreskrifter\/afs-202310\/\"\u003eSwedish Work Environment Authority AFS 2023:10\u003c\/a\u003e, Chapter 12, Sections 4–12, Annex 8. \u003ca href=\"https:\/\/www.av.se\/halsa-och-sakerhet\/artificiell-optisk-stralning\/\"\u003eSwedish Work Environment Authority guidance on artificial optical radiation\u003c\/a\u003e. AI-assisted legal source check, November 26, 2026. No independent legal or technical expert review.\u003c\/p\u003e","brand":"Svenska Dokumentmallar","offers":[{"title":"Default Title","offer_id":56852704919894,"sku":"MB-AOS-2027","price":79.0,"currency_code":"SEK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/2373\/3846\/files\/optisk-stralning-2027-huvudbild.png?v=1795683836","url":"https:\/\/mallbutiken.se\/en\/products\/artificiell-optisk-stralning-uv-ir-industri-2027","provider":"Mallbutiken","version":"1.0","type":"link"}