{"product_id":"msa-gage-rr-matsystemanalys-excel-2027","title":"Measurement Systems Analysis MSA \u0026 Gage R\u0026R 2026\/2027 – 60 measurements, repeatability \u0026 reproducibility | Excel\/Word\/PDF","description":"\u003csection class=\"mb-template-product\" lang=\"en\" style=\"color:#17374c;line-height:1.7;max-width:980px\"\u003e\n\u003ch2\u003eMeasurement System Analysis MSA \u0026amp; Gage R\u0026amp;R 2026\/2027 – Excel, Word and PDF\u003c\/h2\u003e\n\n\u003cp\u003eCan your measurement results be used to control production, assess tolerances, and follow up on quality deviations? Before interpreting a measurement report or an SPC control chart, the \u003cstrong\u003erepeatability and reproducibility of the measurement process itself\u003c\/strong\u003e must be examined. This ready-to-use template package provides structure for \u003cstrong\u003eMSA (Measurement System Analysis) and Gage R\u0026amp;R\u003c\/strong\u003e in a manufacturing environment, featuring an executable spreadsheet for a clearly defined study type and professional reports.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e15 files in one package:\u003c\/strong\u003e 7 editable Word (.docx), 7 searchable A4-PDFs, and an Excel workbook (.xlsx) with nine tabs. Five main Swedish documents, a Swedish guide, and an \u003cem\u003eEnglish User Guide\u003c\/em\u003e. For quality managers, CNC workshops, measurement technicians, and production companies. \u003cstrong\u003ePrice 79 SEK – one-time purchase.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cnav style=\"background:#eaf4f4;padding:12px 17px;border-radius:10px;margin:19px 0\" aria-label=\"Quick links\"\u003e\u003cstrong\u003eOn this page:\u003c\/strong\u003e \u003ca href=\"#mb-msa-innehall\"\u003eContents\u003c\/a\u003e · \u003ca href=\"#mb-msa-filer\"\u003eThe files\u003c\/a\u003e · \u003ca href=\"#mb-msa-excel\"\u003eExcel\u003c\/a\u003e · \u003ca href=\"#mb-msa-arbetsgang\"\u003eWorkflow\u003c\/a\u003e · \u003ca href=\"#mb-msa-metod\"\u003eMethod and responsibility\u003c\/a\u003e · \u003ca href=\"#mb-msa-faq\"\u003eFAQ\u003c\/a\u003e\u003c\/nav\u003e\n\u003cp style=\"background:#f4f8f8;padding:15px;border-left:4px solid #16777d;border-radius:6px\"\u003e\u003cstrong\u003eMethod review October 14, 2026.\u003c\/strong\u003e The support uses a \u003cstrong\u003ecrossed 10×3×2 study\u003c\/strong\u003e with the \u003cstrong\u003eAverage \u0026amp; Range method\u003c\/strong\u003e – not ANOVA. The copyrighted AIAG MSA manual and official forms are not included. The product is not an accredited measurement uncertainty tool, proof of ISO\/AIAG compliance, or an automatic decision on the suitability of a measurement system. The year 2027 denotes the version.\u003c\/p\u003e\n\n\u003cdiv id=\"mb-msa-innehall\" style=\"border:2px solid #cddfe2;border-left:6px solid #16777d;background:#e9f4f4;border-radius:13px;padding:20px;margin:22px 0\"\u003e\n\n\u003ch2 style=\"margin:0 0 10px;font-size:1.32rem\"\u003e01. Package contents\u003c\/h2\u003e\n\n\u003cul style=\"margin-top:0\"\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003e7 Word files:\u003c\/strong\u003e five main Swedish templates, Swedish user guide, and English User Guide.\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003e7 corresponding PDF files:\u003c\/strong\u003e searchable text, A4 format, and print-friendly layout.\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003e1 Excel file:\u003c\/strong\u003e nine sheets with input for 60 measurement values, documented study prerequisites, and linked calculations.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp style=\"margin-bottom:0\"\u003e\u003cstrong\u003eTotal:\u003c\/strong\u003e 15 delivery files in ZIP. \u003cstrong\u003eLanguage:\u003c\/strong\u003e Swedish main documents as well as a Swedish and English guide (not fully bilingual). \u003cstrong\u003eVersion:\u003c\/strong\u003e 1.0 – 2026\/2027. \u003cstrong\u003eDelivery:\u003c\/strong\u003e downloadable digital file, no physical shipping or subscription.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv id=\"mb-msa-filer\" style=\"border:2px solid #cddfe2;border-left:6px solid #17374c;background:#fff;border-radius:13px;padding:20px;margin:22px 0\"\u003e\n\n\u003ch2 style=\"margin:0 0 10px;font-size:1.32rem\"\u003e02. What the files contain\u003c\/h2\u003e\n\n\u003cdiv style=\"overflow-x:auto\"\u003e\n\n\u003ctable style=\"border-collapse:collapse;width:100%;min-width:610px;font-size:.95em\"\u003e\n\n\u003cthead\u003e\u003ctr style=\"background:#17374c;color:#fff\"\u003e\n\n\u003cth style=\"padding:10px;text-align:left\"\u003eNo.\u003c\/th\u003e\n\n\u003cth style=\"padding:10px;text-align:left\"\u003eDocument\u003c\/th\u003e\n\n\u003cth style=\"padding:10px;text-align:left\"\u003eArea of use\u003c\/th\u003e\n\n\u003cth style=\"padding:10px;text-align:left\"\u003eFormat\u003c\/th\u003e\n\n\n\u003c\/tr\u003e\u003c\/thead\u003e\n\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd style=\"padding:10px;border-bottom:1px solid #d4e1e4\"\u003e01\u003c\/td\u003e\n\n\u003ctd style=\"padding:10px;border-bottom:1px solid #d4e1e4\"\u003e\u003cstrong\u003eMSA study plan and assignment\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd style=\"padding:10px;border-bottom:1px solid #d4e1e4\"\u003eStudy ID, measurand, instrument, 10 parts, 3 operators, two measurement rounds, conditions, and authorized start decision.\u003c\/td\u003e\n\n\u003ctd style=\"padding:10px;border-bottom:1px solid #d4e1e4\"\u003eDOCX + PDF\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd style=\"padding:10px;border-bottom:1px solid #d4e1e4\"\u003e02\u003c\/td\u003e\n\n\u003ctd style=\"padding:10px;border-bottom:1px solid #d4e1e4\"\u003e\u003cstrong\u003eSampling and randomization plan\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd style=\"padding:10px;border-bottom:1px solid #d4e1e4\"\u003eSelection of representative parts, blinding, measurement sequence, environment, and traceable registration of two trials.\u003c\/td\u003e\n\n\u003ctd style=\"padding:10px;border-bottom:1px solid #d4e1e4\"\u003eDOCX + PDF\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd style=\"padding:10px;border-bottom:1px solid #d4e1e4\"\u003e03\u003c\/td\u003e\n\n\u003ctd style=\"padding:10px;border-bottom:1px solid #d4e1e4\"\u003e\u003cstrong\u003eGage R\u0026amp;R measurement record\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd style=\"padding:10px;border-bottom:1px solid #d4e1e4\"\u003eOriginal observations for parts P01–P10, operators A–C, and trials 1–2, plus control of 60 data points.\u003c\/td\u003e\n\n\u003ctd style=\"padding:10px;border-bottom:1px solid #d4e1e4\"\u003eDOCX + PDF\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd style=\"padding:10px;border-bottom:1px solid #d4e1e4\"\u003e04\u003c\/td\u003e\n\n\u003ctd style=\"padding:10px;border-bottom:1px solid #d4e1e4\"\u003e\u003cstrong\u003eResults report and interpretation\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd style=\"padding:10px;border-bottom:1px solid #d4e1e4\"\u003eCalculated EV, AV, GRR, PV, TV, %GRR, ndc, method limitations, review, and signature.\u003c\/td\u003e\n\n\u003ctd style=\"padding:10px;border-bottom:1px solid #d4e1e4\"\u003eDOCX + PDF\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd style=\"padding:10px;border-bottom:1px solid #d4e1e4\"\u003e05\u003c\/td\u003e\n\n\u003ctd style=\"padding:10px;border-bottom:1px solid #d4e1e4\"\u003e\u003cstrong\u003eDeviation, action, and restudy\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd style=\"padding:10px;border-bottom:1px solid #d4e1e4\"\u003eNon-conforming measurement system, locking, analysis, actual correction, and effect verification through a new study.\u003c\/td\u003e\n\n\u003ctd style=\"padding:10px;border-bottom:1px solid #d4e1e4\"\u003eDOCX + PDF\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd style=\"padding:10px;border-bottom:1px solid #d4e1e4\"\u003e06\u003c\/td\u003e\n\n\u003ctd style=\"padding:10px;border-bottom:1px solid #d4e1e4\"\u003e\u003cstrong\u003eSwedish user guide\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd style=\"padding:10px;border-bottom:1px solid #d4e1e4\"\u003eStep by step, selection, Excel work, formulas, interpretation, limitations, and technical sources.\u003c\/td\u003e\n\n\u003ctd style=\"padding:10px;border-bottom:1px solid #d4e1e4\"\u003eDOCX + PDF\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd style=\"padding:10px;border-bottom:1px solid #d4e1e4\"\u003e07\u003c\/td\u003e\n\n\u003ctd style=\"padding:10px;border-bottom:1px solid #d4e1e4\"\u003e\u003cstrong\u003eEnglish User Guide\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd style=\"padding:10px;border-bottom:1px solid #d4e1e4\"\u003eEnglish review of the Swedish main templates and workbook; not complete translations.\u003c\/td\u003e\n\n\u003ctd style=\"padding:10px;border-bottom:1px solid #d4e1e4\"\u003eDOCX + PDF\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd style=\"padding:10px;border-bottom:1px solid #d4e1e4\"\u003e08\u003c\/td\u003e\n\n\u003ctd style=\"padding:10px;border-bottom:1px solid #d4e1e4\"\u003e\u003cstrong\u003eExcel – MSA Gage R\u0026amp;R\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd style=\"padding:10px;border-bottom:1px solid #d4e1e4\"\u003eNine sheets: Overview, Study Plan, Measurement Data, Calculation, Traceability, Deviations, Actions, Decisions, and Read me.\u003c\/td\u003e\n\n\u003ctd style=\"padding:10px;border-bottom:1px solid #d4e1e4\"\u003eXLSX\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\n\n\n\u003c\/table\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003ch2 id=\"mb-msa-excel\"\u003eExcel tool with nine tabs and 60 measurements\u003c\/h2\u003e\n\n\u003cp\u003eThe workbook is prepared for ten \u003cstrong\u003ereusable parts (P01–P10)\u003c\/strong\u003e, three \u003cstrong\u003eoperators (A, B, and C)\u003c\/strong\u003e, and two \u003cstrong\u003erepeated measurements\u003c\/strong\u003e per operator and part. This provides a total of \u003cstrong\u003e60 actual observations\u003c\/strong\u003e. Result cells for GRR and variation components remain empty until all 60 numerical values have been entered. No fictitious production data is included.\u003c\/p\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eOverview:\u003c\/strong\u003e clear status indicators, number of registered observations, %GRR, ndc, open deviations, and manual decisions.\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eStudy Plan:\u003c\/strong\u003e item, instrument, characteristic, unit, potential two-sided tolerance, and actual review.\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eMeasurement Data:\u003c\/strong\u003e 30 operator\/part combinations, two trials, automatic range and average, and missing value indicator.\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eCalculation:\u003c\/strong\u003e \u003cstrong\u003eEV\u003c\/strong\u003e (repeatability), \u003cstrong\u003eAV\u003c\/strong\u003e (reproducibility), \u003cstrong\u003eGRR\u003c\/strong\u003e (combined measurement variation), \u003cstrong\u003ePV\u003c\/strong\u003e (part-to-part variation), \u003cstrong\u003eTV\u003c\/strong\u003e (total variation), \u003cstrong\u003e%GRR of TV\u003c\/strong\u003e, and \u003cstrong\u003endc\u003c\/strong\u003e. Optional percentage of two-sided tolerance is shown only with valid input. A chart shows part averages.\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eTraceability, Deviations, Actions, and Decisions:\u003c\/strong\u003e register with responsibility, references, documented effect control, and decisions entered manually.\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eRead me:\u003c\/strong\u003e instructions, fixed statistical constants, method boundaries, and open sources.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch2 id=\"mb-msa-arbetsgang\"\u003eHow to conduct a Gage R\u0026amp;R study\u003c\/h2\u003e\n\n\u003col\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eScope:\u003c\/strong\u003e define what is being measured, the instrument's function, area of use, acceptance criteria, and correct item\/drawing revision.\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eSelect sample parts:\u003c\/strong\u003e select ten real parts that together reflect relevant process variation. The study assumes that each part can be remeasured without changing.\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003ePlan the measurements:\u003c\/strong\u003e choose three competent operators, randomize the order separately for two trials, and blind previous results if possible.\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eCollect original data:\u003c\/strong\u003e enter actual observations into the measurement protocol and then into Excel. Keep part, operator, and trial numbers, as well as instrument and method references.\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eReview calculations:\u003c\/strong\u003e verify that 60 actual measurement values are present and compare the calculated repeatability\/reproducibility against applicable customer and business requirements.\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eMake a separate decision:\u003c\/strong\u003e document limitations, improvement actions, any restudy, and the responsible decision-maker's actual signature.\u003c\/li\u003e\n\n\n\u003c\/ol\u003e\n\n\u003ch2 id=\"mb-msa-metod\"\u003eStatistical method and important limitations\u003c\/h2\u003e\n\n\u003cp\u003eThe \u003cem\u003eAverage \u0026amp; Range\u003c\/em\u003e method used employs two trials, three operators, and ten parts with fixed constants: \u003cstrong\u003eK1 = 0.8862\u003c\/strong\u003e, \u003cstrong\u003eK2 = 0.5231\u003c\/strong\u003e, \u003cstrong\u003eK3 = 0.3146\u003c\/strong\u003e. For example, \u003cstrong\u003eEV = average range × K1\u003c\/strong\u003e, while AV is estimated after correcting for the repeatability contribution. The estimates refer to \u003cstrong\u003e1 standard deviation (1σ)\u003c\/strong\u003e and should not be confused with six-sigma for spread intervals. \u003cstrong\u003e% tolerance\u003c\/strong\u003e uses 6×GRR divided by the valid two-sided tolerance width.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eMethod conditions:\u003c\/strong\u003e this is \u003cem\u003enot\u003c\/em\u003e an ANOVA analysis, and the specific interaction between operator and part is not calculated separately. The method does not replace a measurement uncertainty budget, testing for systematic error (\u003cem\u003ebias\u003c\/em\u003e), linearity, time stability, instrument resolution, or the customer's own acceptance criteria. %GRR can change significantly if the sample parts represent a narrower or wider process range. The suitability of the results must be assessed by an expert.\u003c\/p\u003e\n\n\u003cp\u003eMSA is not a general Swedish government form. Copyrighted manuals or standards should not be assumed to be included. The templates are independently designed as work support based on publicly described metrological methodology, including \u003ca href=\"https:\/\/www.itl.nist.gov\/div898\/handbook\/mpc\/section4\/mpc4.htm\" rel=\"nofollow noopener\"\u003eNIST – Gauge R\u0026amp;R studies\u003c\/a\u003e and \u003ca href=\"https:\/\/www.itl.nist.gov\/div898\/handbook\/mpc\/section4\/mpc46.htm\" rel=\"nofollow noopener\"\u003eNIST – Quantifying uncertainties\u003c\/a\u003e. The product's word choices do not constitute a claim of independent certification.\u003c\/p\u003e\n\n\u003ch2\u003eRelated templates, guides, and categories\u003c\/h2\u003e\n\n\u003cp\u003eA documented measurement system analysis provides a better foundation for \u003ca href=\"\/en\/products\/spc-processduglighet-styrdiagram-cp-cpk-2027\"\u003eSPC \u0026amp; Process Capability with I–MR control charts and Cp\/Cpk\u003c\/a\u003e, where it is important that measurement variation is not confused with process variation. In \u003ca href=\"\/en\/products\/forstastyckskontroll-fai-mattprotokoll-2027\"\u003eFirst Article Inspection \u0026amp; FAI\u003c\/a\u003e, measurements are documented against drawings and established requirements. Also check the gauge's history in \u003ca href=\"\/en\/products\/kalibreringsregister-matdonskontroll-excel-2026-2027\"\u003eCalibration Register \u0026amp; Gauge Control\u003c\/a\u003e. For a broader risk assessment, \u003ca href=\"\/en\/products\/fmea-feleffektanalys-mall-excel-2026-2027\"\u003eFMEA – Failure Mode and Effects Analysis\u003c\/a\u003e is a supplementary support. More products can be found in \u003ca href=\"\/en\/collections\/kvalitetsledning-iso-mallar\"\u003eQuality Management \u0026amp; ISO – Templates\u003c\/a\u003e and \u003ca href=\"\/en\/collections\/produktion-industri-mallar\"\u003eProduction \u0026amp; Industry – Templates\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch2 id=\"mb-msa-faq\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003ch3\u003eHow many measurements are required for this template?\u003c\/h3\u003e\n\n\u003cp\u003eExactly 60 actual measurement values: ten parts times three operators times two trials. Other test setups or destructive testing require a different analysis method or a customized workbook.\u003c\/p\u003e\n\n\u003ch3\u003eWhat is the difference between EV and AV?\u003c\/h3\u003e\n\n\u003cp\u003eEV describes variation when the same operator repeats measurements under the study conditions; AV estimates the variation contribution between operators. GRR summarizes these two components, not all conceivable measurement uncertainty.\u003c\/p\u003e\n\n\u003ch3\u003eIs this an AIAG-certified MSA tool?\u003c\/h3\u003e\n\n\u003cp\u003eNo. The package is based on generally described Gage R\u0026amp;R methodology but is not supplied with a licensed AIAG MSA manual, does not claim AIAG certification, and does not replace customer-specific instructions.\u003c\/p\u003e\n\n\u003ch3\u003eCan Excel automatically approve a measurement system?\u003c\/h3\u003e\n\n\u003cp\u003eNo. The indices are preliminary aids. Approval requires competent evaluation, applicable acceptance criteria, and a separate actually documented decision.\u003c\/p\u003e\n\n\u003ch3\u003eCan I use the package for a CNC workshop?\u003c\/h3\u003e\n\n\u003cp\u003eYes, as a practical aid for non-destructive measurement studies with reusable parts, three operators, and two trials. Check measurement method, fixtures, drawing requirements, and instrument status.\u003c\/p\u003e\n\n\u003ch3\u003eAre the templates available in English?\u003c\/h3\u003e\n\n\u003cp\u003eThe main templates are in Swedish. An English User Guide explains their use but is not a complete translation of all templates.\u003c\/p\u003e\n\n\u003cp style=\"border-top:1px solid #d5e1e4;padding-top:13px;font-size:.92em\"\u003e\u003cstrong\u003eVersion:\u003c\/strong\u003e 1.0 · \u003cstrong\u003eSource and method review:\u003c\/strong\u003e 2026-10-14 · \u003cstrong\u003eDocument package:\u003c\/strong\u003e msa-gage-rr-2027.zip · \u003cstrong\u003eDelivery:\u003c\/strong\u003e digital, after purchase when file connection in Shopify has been verified.\u003c\/p\u003e\n\n\u003caside class=\"mb-seo-guide\" style=\"background:#eef7f7;border-left:4px solid #117981;padding:14px 18px;margin:20px 0;border-radius:8px\"\u003e\u003cstrong\u003eIn-depth about measurement precision:\u003c\/strong\u003e Read our \u003ca href=\"\/en\/blogs\/foretag\/msa-gage-rr-matsystemanalys-upprepbarhet-reproducerbarhet\"\u003eguide to MSA and Gage R\u0026amp;R\u003c\/a\u003e with step-by-step process, checklist, and examples of common errors.\u003c\/aside\u003e\u003c\/section\u003e","brand":"Svenska Dokumentmallar","offers":[{"title":"Default Title","offer_id":55753431679318,"sku":"MSA-GAGE-RR-2027","price":79.0,"currency_code":"SEK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/2373\/3846\/files\/msa-gage-rr-2027-huvudbild_ff01d0f0-fc48-4ba1-a2cb-366ae6d228fd.png?v=1792007852","url":"https:\/\/mallbutiken.se\/en\/products\/msa-gage-rr-matsystemanalys-excel-2027","provider":"Mallbutiken","version":"1.0","type":"link"}