{"product_id":"sakerhets-plc-2027-programandring-versionsbevis-aterstartsprov","title":"Safety PLC 2027 – program change, version evidence and restart test | Word\/PDF\/Excel","description":"\u003cdiv class=\"mb-product-copy\"\u003e\n\n\u003cp\u003e\u003cstrong\u003eAre you going to change a safety PLC program or update the control system's safety logic?\u003c\/strong\u003e Document the difference between the old and new versions, perform a traceable risk triage, plan and conduct controlled safety tests, and make an explicit decision before the plant can be restarted. This specialist package is designed for machine manufacturers, integrators, and machine safety officers in Sweden.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQuick facts:\u003c\/strong\u003e 15 files (7 DOCX, 7 corresponding searchable PDFs, and 1 XLSX with 9 tabs), Swedish legal\/technical working documentation, a Swedish guide, and a separate English user guide. The PDF versions are static and not digitally fillable. \u003cstrong\u003ePrice: SEK 79 upon publication.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cdiv style=\"border:2px solid #8DADCA;border-radius:9px;padding:17px 19px;margin:17px 0;background:#F3F8FC\"\u003e\n\n\u003ch2\u003ePackage contents\u003c\/h2\u003e\n\n\u003cp\u003eFive Swedish working templates in Word and corresponding PDFs: program change request; risk triage and substantial machine change; safety function matrix and test plan; FAT\/SAT and restart test; release decision, rollback, and version evidence. A Swedish user guide and an English User Guide are also included in both Word and PDF. In addition, there is an editable Excel register with nine tabs. \u003cstrong\u003e7 Word + 7 PDF + 1 Excel = 15 customer files.\u003c\/strong\u003e\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"border:2px solid #8DADCA;border-radius:9px;padding:17px 19px;margin:17px 0;background:#F3F8FC\"\u003e\n\n\u003ch2\u003eWhat the files contain\u003c\/h2\u003e\n\n\u003cp\u003eMachine and control system ID, firmware, pre- and post-version, change description, specific assessment of Articles 3.16 and 18, safety functions, test criteria, test results, version hash, actions, responsible parties, stop gates, and a separate decision on technical release and actual restart.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003ch2\u003eWhen is the product useful?\u003c\/h2\u003e\n\n\u003cp\u003eExample: a change in logic for a protective door, emergency stop, safety I\/O, or version change in a PLC\/safety PLC system. The package is also useful when a passed FAT test must be followed by SAT, when the firmware and the program's previous baseline need to be documented, or when a rollback requires new verification.\u003c\/p\u003e\n\n\u003ch2\u003eWhat is included – and what is not?\u003c\/h2\u003e\n\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\n\u003cthead\u003e\u003ctr\u003e\n\n\u003cth scope=\"col\"\u003eWorking file\u003c\/th\u003e\n\n\u003cth scope=\"col\"\u003eSpecific function\u003c\/th\u003e\n\n\u003cth scope=\"col\"\u003eLanguage and format\u003c\/th\u003e\n\n\n\u003c\/tr\u003e\u003c\/thead\u003e\n\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e01 Program change request\u003c\/td\u003e\n\n\u003ctd\u003eDescribe the change, machine identity, version baseline, dependencies, and responsibilities.\u003c\/td\u003e\n\n\u003ctd\u003eSwedish · editable DOCX + searchable PDF\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e02 Risk triage and substantial change\u003c\/td\u003e\n\n\u003ctd\u003eSeparate assessment of the cumulative criteria in Article 3.16, including a\/b criteria and potential manufacturer liability under Article 18.\u003c\/td\u003e\n\n\u003ctd\u003eSwedish · DOCX + PDF\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e03 Safety function matrix\u003c\/td\u003e\n\n\u003ctd\u003eLink risk analysis, protective function, safe behavior, and verifying test cases.\u003c\/td\u003e\n\n\u003ctd\u003eSwedish · DOCX + PDF\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e04 FAT\/SAT test protocol\u003c\/td\u003e\n\n\u003ctd\u003eReport controlled tests, expected results, actual results, evidence of measurements, deviations, and restart tests.\u003c\/td\u003e\n\n\u003ctd\u003eSwedish · DOCX + PDF\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e05 Release decision and rollback\u003c\/td\u003e\n\n\u003ctd\u003eManage technical stop gates, decision-making authority, restoration evidence, and separate commissioning control.\u003c\/td\u003e\n\n\u003ctd\u003eSwedish · DOCX + PDF\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e06 Swedish user guide\u003c\/td\u003e\n\n\u003ctd\u003ePractical sequence, typical cases, limitations, and official sources.\u003c\/td\u003e\n\n\u003ctd\u003eSwedish · DOCX + PDF\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e07 English User Guide\u003c\/td\u003e\n\n\u003ctd\u003eExplains how the Swedish templates are used, with a glossary. Not an English version of the working templates.\u003c\/td\u003e\n\n\u003ctd\u003eEnglish · DOCX + PDF\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e08 Excel register\u003c\/td\u003e\n\n\u003ctd\u003eRecord changes, functions, risk triage, FAT\/SAT, versions, actions, and decisions, and view an overview.\u003c\/td\u003e\n\n\u003ctd\u003eSwedish · editable XLSX\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\n\n\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003ch2\u003eExcel: nine tabs and a traceable chain of control\u003c\/h2\u003e\n\n\u003cp\u003eThe tabs are \u003cstrong\u003eOverview, Changes, Functions, Risk Triage, Testing, Versions, Actions, Decisions, and Read Me.\u003c\/strong\u003e Excel includes controlled status selections and calculations that count, for example, open risk ratings, failed tests, open actions, and items marked “Do Not Release.” The formulas have been tested with synthetic test cases, and the customer file is delivered without test data. \u003cstrong\u003eExcel counts issues – it does not assess machine safety or approve any release.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003ch2\u003eSeven-step workflow\u003c\/h2\u003e\n\n\u003col\u003e\n\n\u003cli\u003eRecord the machine, the program version before the change, and the current firmware.\u003c\/li\u003e\n\n\u003cli\u003eSpecify the changed safety behavior, dependencies, and risk analysis.\u003c\/li\u003e\n\n\u003cli\u003eAssess whether the change falls under the Machinery Regulation's definition of a substantial change.\u003c\/li\u003e\n\n\u003cli\u003eEstablish safety functions and actual test criteria through a qualified expert.\u003c\/li\u003e\n\n\u003cli\u003ePerform verification in an approved, safe test environment; document failed results without overwriting previous evidence.\u003c\/li\u003e\n\n\u003cli\u003eTest requirements for version and intervention traceability, archiving, and the technical file.\u003c\/li\u003e\n\n\u003cli\u003eMake a separate technical decision and then an actual operational\/restart decision according to the organization's safety process.\u003c\/li\u003e\n\n\n\u003c\/ol\u003e\n\n\u003ch2\u003eLegal basis and dates\u003c\/h2\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/eur-lex.europa.eu\/eli\/reg\/2023\/1230\/en\"\u003eThe Machinery Regulation (EU) 2023\/1230, consolidated version\u003c\/a\u003e shall generally apply from \u003cstrong\u003e20 January 2027\u003c\/strong\u003e (Article 54). Certain provisions apply earlier. \u003cstrong\u003eArticle 52\u003c\/strong\u003e contains transitional provisions, meaning that an existing machine does not automatically require a new CE assessment just because someone updates a program.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eArticle 3.16\u003c\/strong\u003e defines a substantial change through several cumulative conditions: including a subsequent physical or digital change that was not planned by the manufacturer, a new hazard or increased risk, and specific protection requirements under points a or b. It is incorrect to call \u003cem\u003eevery\u003c\/em\u003e program change substantial. \u003cstrong\u003eArticle 18\u003c\/strong\u003e may entail manufacturer liability when a substantial change actually exists. \u003cstrong\u003eAnnex III, sections 1.1.9 and 1.2.1\u003c\/strong\u003e cover, among other things, safety-critical software, control systems, and the recording of changes\/updated program versions. \u003cstrong\u003eAnnex IV\u003c\/strong\u003e applies to technical documentation.\u003c\/p\u003e\n\n\u003cp\u003eA specific provision in Annex III, section 1.2.1 f, concerns an intervention log and uploaded versions of safety software for five years after upload for the specified control purpose. This is not a general rule that personal data or secret source code must be archived for five years in an Excel file. Check applicability, confidentiality, data protection, and secure storage separately.\u003c\/p\u003e\n\n\u003cp\u003eSee also \u003ca href=\"https:\/\/www.av.se\/arbetsmiljoarbete-och-inspektioner\/inspektioner-utredningar-och-kontroller\/produktregler-och-marknadskontroll\/produktregler\/krav-pa-maskiner\/den-nya-maskinforordningen\/\"\u003eSwedish Work Environment Authority's information on the new Machinery Regulation\u003c\/a\u003e. Potentially relevant standards, such as ISO 12100, ISO 13849-1, and IEC 62061, require separate competent application; the template package contains no PL\/SIL calculation.\u003c\/p\u003e\n\n\u003ch2\u003eDifference from other machine templates\u003c\/h2\u003e\n\n\u003cp\u003eThis package focuses on \u003cstrong\u003especific program versions, safety function tests, and release\/rollback evidence\u003c\/strong\u003e. For a more comprehensive legal assessment of whether a change is substantial, \u003ca href=\"\/en\/products\/vasentlig-maskinandring-2027-artikel18-gransdragning\"\u003eSubstantial Machine Change 2027\u003c\/a\u003e is also available. For general EU product documentation, see \u003ca href=\"\/en\/products\/eu-maskinforordningen-machinery-regulation-2027-riskbedomning-ce-technical-file-word-pdf-excel\"\u003eEU Machinery Regulation 2027 – Risk Assessment and Technical File\u003c\/a\u003e, and for more general acceptance testing, \u003ca href=\"\/en\/products\/fat-sat-testprotokoll-2026-2027-acceptansprovning-avvikelser-och-excel-word-pdf\"\u003eFAT\/SAT Test Protocol\u003c\/a\u003e. The products serve different purposes.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\n\u003ch3\u003eDoes a program change automatically make the machine a new CE product?\u003c\/h3\u003e\n\n\u003cp\u003eNo. Make a concrete legal and technical assessment according to the applicable regulation and the machine's history. Article 3.16 requires more than the software being changed.\u003c\/p\u003e\n\n\u003ch3\u003eCan we release the machine if Excel shows zero failed tests?\u003c\/h3\u003e\n\n\u003cp\u003eNo. Zero may mean that no test was recorded. The responsible party must ensure an applicable risk assessment, complete verifications, and separate operational approval.\u003c\/p\u003e\n\n\u003ch3\u003eDoes it include a ready-made PLC program or a PL\/SIL calculation?\u003c\/h3\u003e\n\n\u003cp\u003eNo. The product contains administrative templates and verification documentation, not programmable safety logic, established machine parameters, or certification.\u003c\/p\u003e\n\n\u003ch3\u003eAre the PDF files digitally fillable?\u003c\/h3\u003e\n\n\u003cp\u003eNo. The PDFs are searchable and printable reference versions. Use DOCX and XLSX for editing.\u003c\/p\u003e\n\n\u003ch3\u003eAre the working templates available in English?\u003c\/h3\u003e\n\n\u003cp\u003eNo. The five working templates and Excel are in Swedish. An English guide is included to assist with the Swedish documents.\u003c\/p\u003e\n\n\u003ch3\u003eCan we put all PLC source code in Excel?\u003c\/h3\u003e\n\n\u003cp\u003eThis is not recommended. Instead, record secure internal version IDs, hash values, and approved archive references. Limit access to protected documentation and source code.\u003c\/p\u003e\n\n\u003ch2\u003eVersion, delivery, and review level\u003c\/h2\u003e\n\n\u003cp\u003e\u003csmall\u003e\u003cstrong\u003eVersion 1.0 – November 12, 2026.\u003c\/strong\u003e The legal sources have been checked with AI assistance against the consolidated EU regulation and the Swedish Work Environment Authority's information. No independent external legal review, technical functional testing on a real plant, CE assessment, or regulatory certification has been performed. Finalize and review the documents with someone who has expertise in the current machine and function. The digital customer ZIP file should be linked to the download function only when the product is ready for publication. The package is not automatically delivered to buyers at this stage because the product draft is not published.\u003c\/small\u003e\u003c\/p\u003e\n\n\n\u003c\/div\u003e","brand":"Svenska Dokumentmallar","offers":[{"title":"Default Title","offer_id":56588275351894,"sku":"SAFETYPLC-CHANGE-2027-V1","price":79.0,"currency_code":"SEK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/2373\/3846\/files\/01_SafetyPLC_2027_huvudbild_1600.png?v=1794441155","url":"https:\/\/mallbutiken.se\/en\/products\/sakerhets-plc-2027-programandring-versionsbevis-aterstartsprov","provider":"Mallbutiken","version":"1.0","type":"link"}