{"product_id":"stallningsoverlamning-montagekontroll-dokumentjournal-2027","title":"Scaffolding Handover 2026\/2027 – Installation Inspection, Documentation \u0026 Excel | Word\/PDF","description":"\u003csection class=\"mb-product\" lang=\"en\"\u003e\n\u003cp\u003e\u003cstrong\u003eScaffold Handover 2026\/2027\u003c\/strong\u003e is a document package for scaffold contractors, construction companies, and employers who need to document \u003cstrong\u003eassembly inspection, handover documentation, receiver inspection, non-conformities, and ongoing inspections\u003c\/strong\u003e for construction scaffolds in Sweden.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e The templates are administrative and legally limited documentation aids, \u003cstrong\u003enot\u003c\/strong\u003e design calculations, official certificates, completed inspections, or permission to use a scaffold. Actual inspection and risk assessment must be carried out by responsible persons with appropriate competence.\u003c\/p\u003e\n\n\u003cdiv style=\"border:2px solid #315f93;border-radius:10px;padding:17px;margin:17px 0;background:#eff6fc\"\u003e\n\n\u003ch2\u003ePackage Contents\u003c\/h2\u003e\n\n\u003cp\u003e\u003cstrong\u003e15 customer files in a digital ZIP:\u003c\/strong\u003e 7 editable Word (DOCX) files, 7 corresponding searchable and printable PDFs, and 1 Excel workbook (XLSX) with nine tabs. Five main templates and a Swedish guide are in Swedish. A separate English User Guide for the Swedish files is included. The PDFs do not contain interactive form fields.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"border:2px solid #90b0d1;border-radius:10px;padding:17px;margin:17px 0;background:#f9fbfe\"\u003e\n\n\u003ch2\u003eWhat the Files Contain\u003c\/h2\u003e\n\n\u003cp\u003eAssembly inspection, document handover in accordance with AFS 2023:11, the receiver's own inspections, non-conformity and exclusion logs, and registers for ongoing follow-up. The Excel workbook links scaffold ID, responsible parties, verified inspection data, actual document references, and open deficiencies. It provides only administrative statuses, not safety approval.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003ch2\u003eFile by File: What Do I Get?\u003c\/h2\u003e\n\n\u003ctable style=\"border-collapse:collapse;width:100%\"\u003e\n\n\u003cthead\u003e\u003ctr\u003e\n\n\u003cth\u003eDocument\u003c\/th\u003e\n\n\u003cth\u003eFunction\u003c\/th\u003e\n\n\u003cth\u003eLanguage and Format\u003c\/th\u003e\n\n\n\u003c\/tr\u003e\u003c\/thead\u003e\n\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e01 Assembly Inspection\u003c\/td\u003e\n\n\u003ctd\u003eForm for actual inspection after erection in accordance with Chapter 8, Sections 32–33.\u003c\/td\u003e\n\n\u003ctd\u003eSV · Word\/PDF\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e02 Handover Protocol\u003c\/td\u003e\n\n\u003ctd\u003eDocument list for plans, design documentation, inspection documentation, and relevant instructions in accordance with Section 34.\u003c\/td\u003e\n\n\u003ctd\u003eSV · Word\/PDF\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e03 Receiver Inspection\u003c\/td\u003e\n\n\u003ctd\u003eThe user employer's risk assessment and inspection basis before use.\u003c\/td\u003e\n\n\u003ctd\u003eSV · Word\/PDF\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e04 Non-conformities and Exclusions\u003c\/td\u003e\n\n\u003ctd\u003eDocument actual deficiencies, protective measures, and re-inspection.\u003c\/td\u003e\n\n\u003ctd\u003eSV · Word\/PDF\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e05 Ongoing Inspection Log\u003c\/td\u003e\n\n\u003ctd\u003eInspections during use and after specific risk events.\u003c\/td\u003e\n\n\u003ctd\u003eSV · Word\/PDF\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e06 User Guide\u003c\/td\u003e\n\n\u003ctd\u003eWorkflow, allocation of responsibilities, legal sources, and practical scenarios.\u003c\/td\u003e\n\n\u003ctd\u003eSV · Word\/PDF\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e07 English User Guide\u003c\/td\u003e\n\n\u003ctd\u003eEnglish instructions for the Swedish working templates.\u003c\/td\u003e\n\n\u003ctd\u003eEN · Word\/PDF\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e08 Excel Register\u003c\/td\u003e\n\n\u003ctd\u003eNine tabs for assembly inspections, documentation, receivers, deficiencies, and follow-up.\u003c\/td\u003e\n\n\u003ctd\u003eSV · XLSX\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\n\n\n\u003c\/table\u003e\n\n\u003ch2\u003eWho Uses the Templates?\u003c\/h2\u003e\n\n\u003cp\u003eScaffold erectors, construction contractors, and employers who receive and use a construction scaffold. The regulations distinguish between inspection after assembly and the employer's own inspection before and during use. For weather protection, special designs, and multiple employers at a construction site, additional documentation and specific procedures may be required. This package does not produce a design calculation or an actual technical scaffold plan.\u003c\/p\u003e\n\n\u003ch2\u003eWhat Documentation Must Be Handed Over?\u003c\/h2\u003e\n\n\u003cp\u003eAFS 2023:11, Chapter 8, Section 34, covers, among other things, the plan for erection, use, and dismantling, design documentation, documented inspection, and specific instructions for applicable weather protection and prefabricated scaffolds. The user employer also needs to verify access to the documentation in accordance with Section 36. At construction sites with multiple employers, there are specific requirements regarding Bas-U. See the \u003ca href=\"https:\/\/www.av.se\/afs-202311\/\"\u003eSwedish Work Environment Authority regulations\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eExcel with Nine Tabs\u003c\/h2\u003e\n\n\u003cp\u003e\u003cstrong\u003eSTART, SITE, ASSEMBLY INSPECTION, HANDOVER, DOCUMENTS, USER INSPECTION, DEFICIENCIES, FOLLOW-UP, and SOURCES.\u003c\/strong\u003e If the eight administrative handover inspections are marked as verified and no non-conformity has the status “Open” or “In Progress,” \u003cstrong\u003eBASE – MANUAL FINAL REVIEW\u003c\/strong\u003e is displayed. For incomplete inspections or open non-conformities, \u003cstrong\u003eSTOP\/INVESTIGATE\u003c\/strong\u003e is displayed. The status never constitutes a right to use a scaffold.\u003c\/p\u003e\n\n\u003ch2\u003eHow the Document Package Is Used\u003c\/h2\u003e\n\n\u003col\u003e\n\n\u003cli\u003eIdentify the scaffold, site, scaffold erector, and user employer.\u003c\/li\u003e\n\n\u003cli\u003eCollect the actual plan, design documentation, and evidence of competence where required.\u003c\/li\u003e\n\n\u003cli\u003eDocument the actual inspection after assembly.\u003c\/li\u003e\n\n\u003cli\u003eRecord which documents have actually been handed over and to whom.\u003c\/li\u003e\n\n\u003cli\u003ePerform the user's separate risk assessment and inspection before use.\u003c\/li\u003e\n\n\u003cli\u003eFollow up on open deficiencies, exclusions, changes, and ongoing inspections.\u003c\/li\u003e\n\n\u003cli\u003eArchive signed originals and the current version of all supporting documentation.\u003c\/li\u003e\n\n\n\u003c\/ol\u003e\n\n\u003ch2\u003eLegal Limitations\u003c\/h2\u003e\n\n\u003cp\u003eIn accordance with AFS 2023:11, Chapter 8, Sections 32–33, the employer responsible for erection must inspect and document the completed scaffold. In accordance with Sections 35–37, the employer who uses the scaffold has their own risk assessment and inspection obligations. \u003cstrong\u003eA scaffold with a deficiency that is significant for the working environment must not be used until the deficiency has been addressed.\u003c\/strong\u003e Requirements for competence and documentation are also found in Section 24 and Annex 6. The legal and technical content of the documentation must be checked against the actual scaffold.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003ch3\u003eIs the product an approved scaffold certificate?\u003c\/h3\u003e\n\n\u003cp\u003eNo. It helps document work and inspections that are actually carried out. The files do not certify the actual safety of a scaffold.\u003c\/p\u003e\n\n\u003ch3\u003eIs it enough if the scaffold erector has signed?\u003c\/h3\u003e\n\n\u003cp\u003eNo. The user's employer needs to perform their own inspections before and during use in accordance with applicable regulations.\u003c\/p\u003e\n\n\u003ch3\u003eWhat do we do if a deficiency remains?\u003c\/h3\u003e\n\n\u003cp\u003eA deficiency that is significant for the working environment prevents use until it has been addressed. Describe the deficiency, the protective measure, and the actual re-inspection.\u003c\/p\u003e\n\n\u003ch3\u003eDoes it include design and technical construction?\u003c\/h3\u003e\n\n\u003cp\u003eNo. The package provides space for references to technical documentation, but does not produce it.\u003c\/p\u003e\n\n\u003ch3\u003eCan Excel approve the scaffold for use?\u003c\/h3\u003e\n\n\u003cp\u003eNo. Excel only displays administrative supporting information for manual final review or STOP\/INVESTIGATE.\u003c\/p\u003e\n\n\u003ch3\u003eWhat is editable?\u003c\/h3\u003e\n\n\u003cp\u003eThe Word files and Excel workbook can be edited. The PDF files are searchable and printable without interactive fields.\u003c\/p\u003e\n\n\u003ch2\u003eLegal Sources and Version\u003c\/h2\u003e\n\n\u003cp\u003e\u003cstrong\u003eVersion 1.0, internal source review November 22, 2026.\u003c\/strong\u003e \u003ca href=\"https:\/\/www.av.se\/afs-202311\/\"\u003eAFS 2023:11\u003c\/a\u003e, especially Chapter 8, Sections 5, 24–25, and 32–37; the \u003ca href=\"https:\/\/www.av.se\/produktion-industri-och-logistik\/stallningar\/\"\u003eSwedish Work Environment Authority guidance on scaffolds\u003c\/a\u003e with a free sample form for plans; \u003ca href=\"https:\/\/www.av.se\/afs-20233\/\"\u003eAFS 2023:3\u003c\/a\u003e for construction site working environment coordination. No external legal or scaffold expert review has been verified.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eSupplementary documentation:\u003c\/strong\u003e \u003ca href=\"\/en\/products\/fallrisk-arbete-pa-hojd-riskbedomning-fallskyddsplan-2026-2027\"\u003eFall Risk and Work at Height\u003c\/a\u003e covers a broader fall risk assessment; this package covers scaffold handover and inspection logs.\u003c\/p\u003e\n\n\u003c\/section\u003e","brand":"Svenska Dokumentmallar","offers":[{"title":"Default Title","offer_id":56741122769238,"sku":"MB-STALLNINGSOVERLAMNING-2027-V1","price":79.0,"currency_code":"SEK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/2373\/3846\/files\/01_Stallningsoverlamning_Huvudbild_1600.png?v=1795320827","url":"https:\/\/mallbutiken.se\/en\/products\/stallningsoverlamning-montagekontroll-dokumentjournal-2027","provider":"Mallbutiken","version":"1.0","type":"link"}