About this template

Do you sell, import, or stock split air-to-water heat pumps in Sweden? From 1 January 2027, the EU F-gas Regulation will apply a new market ban on certain split air-to-water systems with a maximum capacity of 12 kW and a GWP of 150 or higher. There is a narrow, site-specific exception when safety requirements necessitate it. Therefore, importers, wholesalers, retailers, and installers need to distinguish between actual model variants, legally placed-on-the-market stock, and individual safety cases.

This niche package in Word, PDF, and Excel helps you request the correct manufacturer certificate, document the EU supply chain, identify inconsistent GWP data, and register internal sales blocks. No template issues a legal approval, CE certificate, or installation certificate.

Quick Facts

SEK 79 · Digital ZIP · 15 customer files. Five Swedish work templates, a Swedish user guide, and a separate English User Guide – each in editable Word (DOCX) and searchable, printable PDF (7+7). Also included is a Swedish Excel workbook with nine tabs and 571 control formulas. The PDF copies are not electronically fillable. The English guide provides instructions for the Swedish templates, not seven additional English forms.

01. Package Contents

Five operational Swedish documents: model classification, GWP/supplier letter, proof of first EU market placement, site-specific safety exception, and non-compliance/sales stop. Swedish guide and English User Guide, all seven in both Word and PDF. A Swedish Excel workbook with nine tabs. 7 DOCX + 7 PDF + 1 XLSX = 15 files.

02. What the Files Contain

Fields for the actual manufacturer's model/SKU, nominal kW, refrigerant, F-gas classification, GWP and source, first provision on the EU market, stock series, the supplier's original proof, safety requirements at the operating site, and separate correction checks. The Excel sheet flags, among other things, “STOP”, “INVESTIGATE”, “OLDER EU MARKET – PROOF REQUIRED” and “SAFETY CASE – MANUAL REVIEW”. No status constitutes an automatic legal approval to sell.

Which Companies Can Use the Package?

Swedish heat pump importers, HVAC wholesalers, retailers, e-commerce companies, installation companies, product managers, and quality assurance officers with stock of split air-to-water heat pumps. The product is suitable, for example, for companies that need to assess R32 models with different nominal capacities, investigate which units were first released on the EU market, or require documentation for an alleged safety exception at a specific installation site.

All Files and Features

Document Practical Check Format
01. Classification – split air/water Check actual model, nominal capacity, product category, F-gas/GWP, and first date on the EU market. DOCX + searchable PDF – Swedish
02. Supplier Letter – GWP and Capacity Request model-specific technical certificates, gas identity, marking, and documents on first market placement. DOCX + searchable PDF – Swedish
03. Stock Proof – First EU Market Document the original EU transaction, import/delivery, serial number, and special proof requirements for subsequent stock sales. DOCX + searchable PDF – Swedish
04. Safety Exception – Installation Site Set requirements for the actual safety regulations, actual installation site, tested alternatives, and expert assessment. DOCX + searchable PDF – Swedish
05. Non-compliance and Sales Block Stop and investigate affected products/orders, request correction, and independently verify the action. DOCX + searchable PDF – Swedish
06. Swedish User Guide Step-by-step instructions, five scenarios, differences between split/monoblock and EU sources. DOCX + searchable PDF – Swedish
07. English User Guide English instructions for the Swedish work templates; no separate English legal forms. DOCX + searchable PDF – English guide
08. Excel Register with Nine Tabs Read Me, Overview, Models, Refrigerants, EU Market, Safety Case, Suppliers, Non-compliance, Proof. XLSX – Swedish

What New Rule Comes into Effect on 1 January 2027?

Regulation (EU) 2024/573 of the European Parliament and of the Council Article 11.1 together with Annex IV, point 9(b) prohibits, from 2027-01-01, the first placing on the EU market of split air-to-water heat pumps with a nominal capacity up to and including 12 kW that contain or whose function depends on F-gases with GWP ≥150. This does not apply when such a gas is required to meet safety requirements at the actual operating site. Several conditions must therefore be checked simultaneously; a general GWP claim is not sufficient.

12.0 kW Is Covered – But 12.1 kW Is a Different Assessment

The exact limit is “up to and including 12 kW”. A model with a certified 12.0 kW capacity may be covered by point 9(b), while an actual nominal capacity over 12 kW must be assessed against other relevant provisions and dates. Never use an approximate sales name, such as the “12 Series”, as a substitute for the manufacturer's actual technical data.

GWP 150 Is Included in the Limit

GWP 150 or higher triggers the 9(b) assessment when the other conditions are met. A commonly used refrigerant such as R32 has a GWP higher than 150, but the value and legal classification must always be substantiated from the correct source for the specific product configuration. Excel does not derive any GWP solely from the refrigerant's name.

Monoblocks and Split Air-to-Air Have Different Rules

Standalone heat pumps and monoblocks are covered by separate parts of Annex IV, point 8, with their own limits. Split air-to-air ≤12 kW with GWP ≥150 is covered by a different ban date: 1 January 2029, according to point 9(c). Certain single-split systems have already been covered by point 9(a) since 2025. Do not treat all heat pumps as the same system category. The EU Commission's product type overview explains the difference.

What Happens to Heat Pumps Already in Stock?

Article 11.1 distinguishes first placing on the market from subsequent provision. From 1 January 2028, one year after point 9(b)'s ban date, subsequent provision of equipment that was lawfully placed on the EU market before the ban must be accompanied by proof of the earlier lawful market placement. An earlier purchase order or a “stock 2026” label does not automatically prove this. The templates document the transaction chain, actual delivery events, invoice references, and serial numbers.

Safety Exception – An Actual Site Requirement, Not a Standard Answer

For point 9(b), a relevant safety requirement at the operating site must actually justify the use of the gas in question. A supplier's general statement about higher costs or that “alternatives are difficult to install” is not an automatically valid exemption. Document the actual installation site, applicable safety standards, alternative assessment, technical expert, and legal decision-making basis. The GWP 750 exception in some other equipment categories must not be incorrectly applied to point 9(b).

Excel – Nine Tabs with Actual Workflows

Read Me, Overview, Models, Refrigerants, EU Market, Safety Case, Suppliers, Non-compliance, Proof. The workbook contains 571 pre-built formulas and data validation. A model with a relevant GWP ≥150 that is first placed on the market in 2027 is shown with an internal stop flag; an earlier placed-on-the-market model requires proof; a reference to a safety case only allows for manual review. For internal non-compliance, completed action, separate verification, and a proof ID are required to achieve the status Verified Internal Correction. 46 out of 46 scenario tests passed. The customer version is reset without fictitious test products.

How the Package Is Used in Seven Steps

  1. Identify the model, exact variant, and actual product category.
  2. Request the manufacturer's proof of nominal kW, F-gas classification, refrigerant, and source-substantiated GWP.
  3. Check which point in Annex IV and which actual ban date applies.
  4. Document the date of first lawful EU market placement, and stock proof for subsequent sales when relevant.
  5. Check any safety exceptions against the actual site and technical documentation.
  6. Register relevant models, suppliers, and proof in Excel.
  7. Block internal sales flows for unresolved non-compliance; do not reset to normal status without verified correction.

Frequently Asked Questions

Are All Air-to-Water Heat Pumps Banned from January 2027?

No. Point 9(b) applies to split air-to-water systems with a nominal capacity up to and including 12 kW that use or depend on F-gases with GWP ≥150, with an explicit safety exception. Other product categories and gases must be assessed separately.

Can I Continue to Sell My 2026 Stock?

It depends on whether the equipment was actually lawfully placed on the EU market before the correct ban date. For subsequent provision from January 2028, explicit proof of the earlier lawful market placement is required under Article 11.1. An old purchase date is not sufficient documentation in itself.

Is a Heat Pump with a GWP of Exactly 150 Within the Limit?

Yes. The current limit includes GWP 150 and higher, provided all other conditions are met.

Can I Claim a Safety Exception with a General Supplier Certificate?

No, not without checking whether the requirement actually applies to safety at the actual operating site. The basis must be linked to the correct installation and the correct provision.

Can Excel Automatically Determine That Our Stock Sale Is Lawful?

No. Excel only shows administrative documentation and risk flags, never regulatory decisions, approved products, or a legal certificate of sale.

Does It Include Certified Installation, Refrigerant Check, or CE Marking?

No. The F-gas Regulation's rules on marking, installer certificates, and leak checks, as well as other product safety rules, are separate and must be followed regardless of this document package. See the Swedish Environmental Protection Agency's guidance.

Other Mallbutiken Templates – Avoid the Wrong Product

F-gas in Heat Pump Sales – Installation Proof and Certificate Check covers installation and purchase checks. F-gas Leakage – Repair and Post-Check handles leaks and service logs. Compressed Air Dryers 2027–2030 covers a separate EU exception for refrigerated dryers. This product specifically applies to split air-to-water ≤12 kW, the 2027 GWP 150 market ban, lawful market placement proof, and site-specific safety exceptions.

Legal Sources and Legal Quality

Version 1.0 · AI-assisted legal source check November 16, 2026. Primary sources: Regulation (EU) 2024/573, Article 11 and Annex IV, point 9(b), the EU Commission's guidance on F-gases in AC and heat pumps, and the Swedish Environmental Protection Agency's Swedish F-gas guidance. No external legal review, regulatory review, accredited technical check, or installation has been performed. The product's facts must be adapted to the actual model, refrigerant, EU supply chain, site, and applicable law. Digital download (ZIP), not a cloud service or regulatory integration.