About this template

Prepare the documentation for in-house medical devices for in vitro diagnostics before 26 May 2028. The template package helps quality managers at healthcare institutions and laboratories describe the needs of the target patient group, search for equivalent products on the market, compare performance data, and document their justification in accordance with Article 5.5(d) of the IVDR. It is a defined working document, not clinical validation or a decision on regulatory compliance.

Package contents

Digital ZIP, version 1.0. Five Swedish working templates, a Swedish user guide and an English User Guide in seven editable Word files and seven corresponding searchable PDF files, plus a Swedish Excel workbook. 15 customer files in total.

What the files contain

Patient needs, market search, performance comparison, justification of needs and re-evaluation. The Excel workbook has nine tabs and 40 pre-formatted rows in each of the seven working registers.

Who is the template package for?

Swedish healthcare institutions investigating in-house IVD products within their own legal entity. For example, quality managers, regulatory managers and medical experts at laboratories. The scope applies to non-industrial in-house manufacturing under the IVDR, not commercial manufacturing, MDR products or products for performance studies. Individual assessments require competent staff.

Document list – file by file

Document Format/language Use
01 Patient needs and application DOCX/PDF, Swedish Intended purpose, patient group, criteria and responsibilities
02 Market search DOCX/PDF, Swedish Search method, alternative products, sources and knowledge gaps
03 Performance comparison DOCX/PDF, Swedish Expert-reviewed evidence, comparability and counterarguments
04 Justification of needs under 5.5(d) DOCX/PDF, Swedish Justification or continued investigation, references and decision
05 Re-evaluation and follow-up DOCX/PDF, Swedish Changes, responsibilities, evidence and actions
06 Swedish user guide DOCX/PDF, Swedish Workflow, examples, legal sources and scope
07 English User Guide DOCX/PDF, English English guidance for the Swedish working templates
08 IVDR register XLSX, Swedish Nine tabs for market and needs investigation

How the template package is used

  1. Define the intended purpose, target patient group, special needs and objectively justified performance criteria.
  2. Document the market search with search date, sources, search terms, scope and relevant alternative products.
  3. Compare technical, biological and clinical data with the help of competent reviewers. Retain counterarguments and uncertainty.
  4. Compile a justification of needs with references, or leave the question open if no data is available. An alternative that meets the needs should not be overlooked.
  5. Follow up changes in the market, patient needs and product versions. Manage other regulatory requirements within the institution's quality system.

What changes on 26 May 2028?

Article 5.5(d) of Regulation (EU) 2017/746 requires a documented justification of why the special needs of the target patient group cannot be met, or not at an appropriate performance level, by an equivalent product on the market. The application date is specified in Article 113(3)(j), introduced by Regulation (EU) 2022/112. This is not a general extension for in-house manufacturing: the relevant requirements in Annex I and other applicable conditions in Article 5.5 must be met according to their own dates.

Market comparison and documented evidence

Start with the intended purpose and the actual needs of the patient group. Document which sources were searched and which alternatives were assessed. Use reviewed and comparable performance data and report knowledge gaps. MDCG 2023-1, section 3.6, provides guidance on justification and equivalence. A lack of search results, cost, or preference is not in itself evidence that an equivalent alternative is missing. The template contains no automatic score thresholds or pre-filled conclusions.

Excel – market and needs register

Nine tabs: Overview, Products, Searches, Alternatives, Comparisons, Justifications, Evidence, Re-evaluation and Sources. 301 formula cells, 40 pre-formatted rows in each working register, status lists and checks for missing data, duplicate IDs, unknown references and missing verification evidence. Re-evaluation includes a check of manually entered expiry dates that have passed. Nine print areas and seven repeated register headers are pre-formatted.

Fictitious example: P-01 has a special need for a specific test type. Market alternative A-01 has unclear support for the test type. Record the comparison as Under Investigation and request documented data. An OK signal in Excel only indicates an administrative check, not equivalence, clinical performance or approved in-house manufacturing.

Other requirements, IVO and safe handling

Other conditions in Articles 5.5(a)–(c) and (e)–(i), as well as applicable general safety and performance requirements in Annex I, must be managed separately. This includes conditions for internal use, quality management systems and the laboratory's compliance with EN ISO 15189 or applicable national provisions. See IVO's guidance on in-house manufacturing and adverse events. Public declaration under (f) and information to IVO under (e) and HSLF-FS 2021:32, Chapter 4, Section 2, are not included. Do not record identifiable patient data in the workbook. In case of safety issues, follow the institution's regular patient safety procedures.

File format, language and related templates

Unzip the ZIP file. DOCX is editable, PDF is searchable and intended for reading and printing, and Excel requires a compatible spreadsheet program. The working templates and Excel are in Swedish; the English guide describes the workflow. The thumbnails show actual excerpts from the working template and workbook. For another regulatory requirement, interruption of supply under Article 10(a), see Medical Devices – Interruption of Supply.

Frequently Asked Questions

When does Article 5.5(d) of the IVDR apply?

On 26 May 2028, according to Article 113(3)(j), introduced by Regulation (EU) 2022/112. Other conditions have their own application dates, and several already apply.

What should the justification of needs show?

The institution must justify that the special needs of the target patient group cannot be met, or not at an appropriate performance level, by an equivalent product on the market.

Who may use the exemption for in-house manufacturing?

Healthcare institutions within the EU when all applicable conditions are met. This does not include industrial manufacturing or transfer to another legal entity.

Is it enough if the market search yields no results?

No. Document the scope of the search, sources, limitations and any alternatives. The evidence must be assessed by competent staff.

Can price be the sole justification?

No. Document special patient needs and an appropriate performance level, not just price or preference.

Does Excel determine if a product is equivalent?

No. Control formulas show administrative documentation gaps. Equivalence and performance require expert assessment.

What do we do when a new alternative emerges?

Document the new information and assess the need for re-evaluation. A later available equivalent product does not automatically invalidate the original justification according to MDCG 2023-1.

Does it include a public declaration or IVO form?

No. Article 5.5(f) and information to IVO under Article 5.5(e) and HSLF-FS 2021:32 are managed separately.

Does it include laboratory validation or CE marking?

No. The package is an administrative working aid for the justification of needs. It does not replace Annex I, quality systems, performance evaluation or other conditions.

Which formats and languages are included?

Five Swedish working templates, Swedish and English user guides in DOCX/PDF, plus Swedish XLSX. 15 files in total.

Legal sources

IVDR (EU) 2017/746, Article 5.5, Annex I and Article 113(3)(j); Regulation (EU) 2022/112; MDCG 2023-1, section 3.6; IVO's guidance. AI-assisted legal source check 26 November 2026. No independent legal, clinical or laboratory technical expert review. Check the current legal status before use.