Skip to product information
1 of 3

Svenska Dokumentmallar

Pressure testing 2026/2027 – Overpressure and vacuum, risk assessment, regulatory bodies & Excel | Word/PDF/Excel

Pressure testing 2026/2027 – Overpressure and vacuum, risk assessment, regulatory bodies & Excel | Word/PDF/Excel

File format
DOCX, PDF, XLSX
Document language
Five Swedish work templates Swedish guide English guide and Swedish Excel register
Number of files
7

Digital download. No physical product is shipped.

Regular price $8.00 USD
Regular price Sale price $8.00 USD
Sale Sold out
Taxes included.
View full details

About this template

Prepare and follow up on professional testing with overpressure or underpressure using a comprehensive documentation package in accordance with AFS 2023:13, Chapter 12. The templates help employers, clients, KMA coordinators, and technically responsible persons arrange risk assessments, technical documentation, control bodies, and non-conformities. They are not testing instructions, technical dimensioning, proof of competence, or safety approval.

Package Contents

Digital ZIP, version 1.0, with 15 files: seven editable DOCX files, seven corresponding searchable PDF files, and one Excel workbook. Five Swedish work templates, a Swedish user guide, and an English guide to the Swedish documents.

What the Files Contain

Decision-making before testing, written risk assessment, testing documentation, control bodies, and ordering, as well as non-conformities and follow-up inspections. Excel has nine tabs and 40 pre-formatted rows in each of the seven work registers.

Who Is the Template Package For?

For workshops, industrial companies, and other professional clients or employers who need to document the conditions for testing with overpressure or underpressure. The package is an administrative work aid for competent responsible persons. It does not cover explosive testing or tire inflation. Prescribed inspection of pressurized equipment and other applicable regulations, such as AFS 2023:11, must be assessed separately.

Document List

Document Format/Language Use
01 Decision-making before pressure testing DOCX/PDF, Swedish Application, object, previous inspection, medium, and continued investigation
02 Written risk assessment DOCX/PDF, Swedish Risk source, severity, risk area, preventive measures, and decision
03 Testing documentation and equipment DOCX/PDF, Swedish Technical references, setup, functional check, and documentation evidence
04 Control bodies and ordering DOCX/PDF, Swedish Scope of accreditation, verified decision-making, order, and report
05 Non-conformity and follow-up inspection DOCX/PDF, Swedish Interruption, root cause investigation, corrective action, and inspection evidence
06 Swedish user guide DOCX/PDF, Swedish Workflow, regulatory map, examples, and sources
07 English User Guide DOCX/PDF, English English guidance to the Swedish documents
08 Testing register XLSX, Swedish Nine tabs for objects, risks, documentation, control bodies, equipment, non-conformities, and actions

How the Template Package Is Used

  1. Identify the object and document the purpose, previous inspections, and changes. Let a competent responsible person determine the application of Chapter 12.
  2. Document risks and severity before testing, as well as references to the assessed risk area and protection.
  3. Collect technical documentation and documented inspections of the equipment. Record references and responsible persons without replacing the technical assessment.
  4. Check the performer's current accreditation and scope when required. Any exception must be assessed and supported separately.
  5. Follow up on non-conformities and corrective actions with dated evidence. Leave decisions on continued work and operation to the competent responsible person.

Legal Basis – AFS 2023:13, Chapter 12

Sections 1–3 regulate application and definitions. Sections 4–13 cover, among other things, written risk assessment, risk area, assessment of the object's durability, suitability of the equipment, and documented inspections. In the event of defects or deviations from the testing process, testing must be immediately interrupted and the equipment depressurized in accordance with Section 13. Sections 14–20 refer to overpressure testing, medium, and gas testing; Sections 21–22 deal with underpressure testing. Always follow applicable regulations and established safe work procedures.

Control Bodies, Pressure Medium, and Scope

Suitable liquid should be used primarily for overpressure testing. If the equipment cannot be completely filled or if filling is uncertain, the rules for gas testing in Section 18 apply. For gas testing, Section 19 generally applies regarding the competent control body; Section 20 contains specific exceptions from the accreditation requirement. Check the scope in the Swedac accreditation register and document the competent decision-making. Exceptions do not mean that other safety requirements are waived. The templates contain no automatic exemption decisions, test pressure calculations, or safety distances.

Excel – Testing and Inspection Register

Nine tabs: Overview, Object, Risks, Documentation, Control Bodies, Equipment, Non-conformities, Actions, and Sources. The register contains 301 formula cells, input fields, status lists, control signals, and 40 rows per work register. Formulas highlight, among other things, duplicate IDs, unknown object references, missing information, verified actions without a date or evidence reference, and manually entered expiration dates that have passed. Nine print areas with page-width adjustment and repeated register headers are prepared.

Fictional documentation example: Object O-01 lacks a clear reference to a previous inspection. Record risk R-01 and request a competent assessment. Link the report in Documentation. An action marked Verified without a date or evidence will receive a control signal if evidence is missing. A complete register row does not mean that testing may be started or resumed.

Format, Language, and Safe Use

Unzip the ZIP file. Word is editable, PDF is searchable, and intended for reading and printing. Excel requires a compatible spreadsheet program that supports formulas and data validation. The work templates and Excel are in Swedish. The English guide describes the use of the Swedish documents. The thumbnails show actual excerpts from the documents and workbook. In case of uncertain work: refrain from testing and hire a competent responsible person.

Related Documents

For ongoing inventory and inspection monitoring, see Pressure Vessels and Expansion Vessels – Equipment Register. For broader workplace safety work, see Safety Rounds and Workplace Safety Rounds.

Frequently Asked Questions

What is pressure testing according to AFS 2023:13?

Testing covered by Chapter 12 may refer to overpressure or underpressure and, among other things, pressure testing, tightness testing, or leak detection. The application must be assessed based on the individual object and work.

Must the risk assessment be in writing?

Yes. Chapter 12, Section 4 requires that the risk assessment be documented in writing and state the risks and whether they are serious.

Is all leak detection exempt?

No. Section 1 states the conditions for the exemption: previous prescribed pressure inspection, no subsequent repairs, modifications, or part replacements, and that the design pressure and maximum operating pressure are not exceeded.

Which pressure medium applies primarily?

For overpressure testing, suitable liquid should be used primarily in accordance with Section 14. The choice must be made by a responsible competent person, not by the Excel register.

What if complete liquid filling is uncertain?

According to Section 18, the provisions for gas testing in Sections 19–20 then apply.

Must the control body be accredited?

For pressurization with gas, the general rule in Section 19 applies regarding an accredited control body or equivalent EEA organization. Section 20 states specific exceptions from the accreditation requirement, not from other safety requirements.

Can Excel determine if an exception applies?

No. The workbook documents verified documentation and references. It does not determine application, competence, test pressure, or risk area.

How is a non-conformity handled during testing?

Section 13 requires immediate interruption and that the equipment be depressurized if defects or deviations from the normal testing process are discovered. Follow established safe procedures.

Is a completed register a safety approval?

No. Administrative control signals refer to documentation status. The employer's responsibility, prescribed inspection, and technical assessment remain.

Which file formats and languages are included?

Five Swedish work templates and two guides, one Swedish and one English, in Word and PDF, as well as a Swedish Excel register. 15 files in total.

Legal Sources

Swedish Work Environment Authority Regulations AFS 2023:13, Chapter 12, Sections 1–22; Swedish Work Environment Authority Guidance on Testing with Under- or Overpressure; Swedac Accreditation Register. AI-assisted legal source check November 26, 2026. No independent legal or technical expert review.