About this template
Will personal alarms stop working when 2G and 3G networks are shut down? For municipalities, home care providers, and those responsible for alarms, it is not enough to replace a SIM card or check that a device is marked “4G”. The entire alarm chain must be traceable: button press, communication network, alarm receiver, any two-way communication, escalation, and confirmed response.
This template package provides structured Word, PDF, and Excel documents to inventory dependencies on older mobile networks, ensure a safe transition, document tests, and decide on feasible backup procedures.
Package contents
15 customer files: five Swedish operational templates, a Swedish user guide and an English User Guide, each in Word (DOCX) and searchable, printable PDF; plus a nine-tab Excel workbook. Total: 7 DOCX + 7 PDF + 1 XLSX. The PDF files do not contain interactive form fields.
What the files contain
Coded alarm inventory, operator and network dependency check, risk assessment, manually decided backup procedure, migration order, actual end-to-end chain test, supplier confirmation, separate care operation decision, and documentation of alarm deviations. No automatic safety assessment or operational approval.
Who needs the personal alarm templates?
Home care, municipal care, LSS services, private care providers, welfare technology coordinators, safety officers, and supplier coordinators who need to move older personal alarms from 2G/3G to modern, functioning communication.
What is included – working documents for working documents?
| File | Use | Format and language |
|---|---|---|
| 01 Inventory and network dependency | Coded alarm IDs, model, firmware, SIM, operator, voice/data, and proof of network support. | SV · DOCX + PDF |
| 02 Risk and backup procedure | Risk scenario, consequences, alternative safety response, and decision-making responsibility. | SV · DOCX + PDF |
| 03 Migration order | Supplier functional and evidence requirements, deployment, and outstanding points. | SV · DOCX + PDF |
| 04 Alarm chain test | Test of button, network, center, voice, escalation, and receipt/response confirmation. | SV · DOCX + PDF |
| 05 Alarm errors and information | Fact-based error report, protective measure, conditional notification, and separate return. | SV · DOCX + PDF |
| 06 Swedish user guide | Eight-step flow, legislation, privacy, and control points. | SV · DOCX + PDF |
| 07 English User Guide | Instructions for the five Swedish operational forms and workbook. | EN · DOCX + PDF |
| 08 Excel register | Nine tabs for administrative traceability and follow-up. | SV · XLSX |
Excel – nine tabs for the entire migration
Overview, Devices, Operators, Risks, Replacements, Chain Test, Deviations, Information, and Read Me. Eight administrative indicators track the number of inventoried alarms, unknown network dependencies, risk cases, ordered replacements, registered chain tests, tests with remaining deviations, error cases, and information entries. All key figures are administrative, not safety certifications. No macros or external data connections.
Examples from operations
Older mobile personal alarm: the alarm units appear to work but depend on a shut down or soon to be decommissioned network. Document the model, network, voice function, and actual risk before replacement.
The supplier has changed the modem: the service confirmation is not enough. Document the entire chain test, including that the alarm center actually receives the alarm and that the correct responder confirms response.
Technical error during an ongoing care response: document a decided and actually staffed backup procedure, the alarm deviation, and how those responsible are informed, without exposing sensitive user data in an open spreadsheet.
How to use the package
- Inventory affected alarm units with coded IDs, without unnecessary personal data.
- Check the device's actual network and communication dependencies against the supplier's original evidence and current operator notification.
- Assess consequences and decide on any temporary alternative safety responses.
- Order migration and documented tests, with responsibility and requirements for original data.
- Perform secure end-to-end tests with the alarm center and responder participating.
- Keep technical test confirmation and the care operation's decision on continued use separate.
- Follow up on outstanding points, recurring checks, and deviations in the operation's management system.
Legal and technical basis – what applies in 2026/2027?
The Swedish Post and Telecom Authority (PTS): technology shift describes the decommissioning of 2G/3G networks. Several networks have already been shut down; Telia plans to decommission the remaining 2G network by the end of 2027. Check the current operator's plans – dates are not a general operational guarantee.
PTS: municipalities need to act mentions personal alarms as an example of municipal equipment that may be affected. The Swedish National Board of Health and Welfare's SOSFS 2011:9 regulates systematic risk analysis, self-monitoring, deviation management, and documentation for covered operations.
The Swedish National Board of Health and Welfare's support on welfare technology clarifies that the technology needs to be adapted to the individual's circumstances. IMY's GDPR guidance means, among other things, that processing must be limited to necessary personal data and that adequate protection is required.
Frequently asked questions
Do all personal alarms marked “4G” work?
Not necessarily. Subscription, voice function, data service, coverage, firmware, alarm center, and escalation must work together. Verify the delivery in the actual alarm chain.
Are all 2G networks decommissioned in 2026?
No. According to PTS, Telia's remaining 2G network is planned to remain until the end of 2027; other operators' networks have already been shut down. Always check current operator information.
Can Excel approve a personal alarm unit?
No. Excel counts case status and evidence entries, not actual personal safety or whether the device may be used. Technical tests and care decisions must be documented separately.
Does the package contain a universal test frequency?
No. SOSFS 2011:9 is based on the operation's risk and needs. Application, actual test frequency, and technical instructions must be determined by those responsible.
Can I put users' names, personal identity numbers, and addresses in Excel?
The workbook is designed for coded alarm IDs and administrative data. Complete user, health data, and care documentation must, if necessary, be processed in a separate, access-controlled system according to applicable rules.
Is the product a technical certificate or a certification?
No. No actual alarms or alarm centers have been tested through the package. It consists of templates for documentation and is not an independent safety approval.
Are the main templates translated into English?
No. Five operational templates and the Excel workbook are in Swedish; a separate English user guide is included. The PDF files are searchable and printable but not interactively fillable.