Svenska Dokumentmallar
Electromagnetic Fields (EMF) 2026/2027 – Risk Assessment, Measurement Data, Access & Action Plan | Word/PDF/Excel
Electromagnetic Fields (EMF) 2026/2027 – Risk Assessment, Measurement Data, Access & Action Plan | Word/PDF/Excel
- File format
- DOCX, PDF, XLSX
- Document language
- Five Swedish work templates Swedish quick start guide English guide and Swedish Excel register
- Number of files
- 7
Digital download. No physical product is shipped.
Couldn't load pickup availability
About this template
Electromagnetic fields (EMF) – risk assessment and control register is a coordinated template package for Swedish employers with, for example, welding equipment, induction heaters, or other sources of electromagnetic fields. Document which sources exist, affected work activities, direct and indirect risks, the need for expert exposure assessment, access conditions, and follow-up of measures in accordance with AFS 2023:10, Chapter 13. The package is an administrative work aid, not a measurement method, medical assessment, or certificate of safe exposure.
Package contents
15 customer files: 7 editable Word (DOCX), 7 corresponding searchable PDF, and an Excel register (XLSX) with seven tabs. Five Swedish work templates, Swedish start guide, and English user guide. Digital ZIP, version 1.0.
What the files contain
Source inventory, risk assessment basis, ordering and receipt of expert report, access and adaptation basis for particularly exposed, as well as action plan and follow-up. Excel links five work registers through unique IDs and shows seven administrative key figures.
Who needs templates for electromagnetic fields?
For employers, production managers, occupational environment coordinators, and KMA managers in industry, workshops, and service who need to structure the documentation of EMF risks. Use the templates for new machines, changed processes, expert measurement assignments, and follow-up. Special provisions or exemptions must be assessed separately; the package does not apply to long-term effects or touching energized conductors. For overall occupational environment work, there is the SAM occupational environment package, and for noise and vibrations, there is a separate exposure package.
Document list
| Document | Function | Format and language |
|---|---|---|
| 01 Source inventory | Equipment, operating conditions, exposure, affected functions, basis, and responsibility | Word/PDF · Swedish |
| 02 Risk assessment | Direct and indirect effects, particularly exposed, multiple sources, action levels, and limit values | Word/PDF · Swedish |
| 03 Measurement basis | Ordering, method and competence basis, report receipt, and supplementation | Word/PDF · Swedish |
| 04 Access and particularly exposed | Area conditions, signage, protected contact routes, information, and review | Word/PDF · Swedish |
| 05 Action plan and follow-up | Immediate protective measures, causes, responsible person, deadline, evidence, and follow-up | Word/PDF · Swedish |
| 06 Start guide | Practical workflow, fictitious example, sources, and limits | Word/PDF · Swedish |
| 07 User Guide | English guidance for Swedish work templates and workbook | Word/PDF · English |
| 08 Control register | Five registers, seven key figures, and source references | Excel · Swedish |
How to use the package
- Inventory equipment and interacting sources. Identify operating modes, location, affected work activities, workers, and basis with a unique source ID. State unknown information as an investigation need.
- Assess direct and indirect risks and particularly exposed groups with the support of current risk assessment. Also document the applicability of manufacturer information. If further detailed risk assessment is deemed unnecessary, document the reasons in accordance with Section 19.
- Order competent assessment, measurement, or calculation when necessary. Save the report with method, measurement quantity, frequency, unit, relevant operating conditions, uncertainty, and conclusion. The form does not replace expert method selection.
- Determine local conditions and appropriate signage and access restriction where requirements apply. Adapt measures for particularly exposed persons. Store individual information separately with restricted access; do not register diagnoses in the coordination register.
- Follow up on measures, inform and educate those affected. Document actual correction and separate decision, and revise the risk assessment regularly and when relevant changes occur.
Excel – from inventory to verified follow-up
The workbook has seven tabs: Overview, Sources, Assessments, Measurement basis, Access, Measures, and Source reference. Five work registers have 100 prepared rows each. The overview counts registered sources, assessments, measurement basis, areas, measures that have not been completely documented as closed, overdue complete entries, and control flags. Control columns highlight duplicate IDs, missing source references, unknown assessment references, and closures that lack evidence or date. Drop-down lists are available for central status fields. The register does not calculate exposure, limit values, or safety distances, nor does it provide automatic safety approvals.
Fictitious example: K-01 refers to an induction heater. Assessment B-01 lacks sufficient basis, so a measurement assignment M-01 is ordered and a measure A-01 is registered with a responsible person and due date. When the report arrives, its reference is registered. If A-01 is marked closed without an evidence reference, follow-up, and decision date, the entry is flagged. The authorized function assesses actual results separately.
Legal basis – AFS 2023:10
AFS 2023:10, Chapter 13 regulates EMF in the workplace. Sections 7–8 apply to risk assessment; Sections 9–13 and Annexes 10–18 deal with, among other things, action levels, limit values, and special conditions; Sections 14–16 apply to assessment, measurement, or calculation, and competence; Section 19 applies to documented reasons and updates; Sections 20–24 refer to preventive measures and protection for particularly exposed, as well as signage. Sections 27–30 deal with, among other things, exceedances, information, and health examination. Upon confirmed exceedances of applicable limit values, the employer shall act immediately in accordance with Section 27. Action level and limit value are different concepts, and an exceeded action level is not automatically a confirmed exceeded limit value. According to Section 21, an action plan is required for exceeded relevant action levels, with the exception specified in the regulation when limit values are not exceeded and safety risks can be ruled out. Sections 22–23 require measures for indirect risks and particularly exposed regardless of a simple numerical comparison.
See the Swedish Work Environment Authority's EMF guidance and Prevent's free guidance. These can be used together with the templates. Legal sources checked November 26, 2026. No independent legal or technical expert review.
Frequently Asked Questions
Must electromagnetic fields be risk assessed?
The employer shall assess the direct and indirect risks caused by EMF. If further detailed assessment is unnecessary, the reasons may be documented in accordance with Section 19.
Do I always have to measure the fields?
No. Assessment with relevant basis may suffice; measurement or calculation is needed when sufficient information cannot be obtained in any other way. Let a competent person assess the need.
Is an action level the same as a limit value?
No. Action levels help assess compliance and the need for measures. Limit values and action levels have different functions and should be assessed against the correct annex and situation.
Is there a general safe distance from an induction heater?
No, the package does not provide general distances. Assess actual fields, frequencies, operating modes, location, and particularly exposed with relevant expert basis.
How are workers with implants or pregnant women handled?
Consider their special risks in accordance with Sections 8, 22, and 23. Individual assessment and adaptation may be required. Handle medical information separately and hire competent support where needed.
Is Excel a measurement calculator?
No. The workbook compiles administrative entries and checks for certain missing information. It does not calculate field strengths or medical risks.
Can I use the templates for multiple machines?
Yes, each source gets a unique ID and can be linked to multiple assessments, measurement basis, access areas, and measures. Five registers have 100 prepared rows each.
What formats and languages are included?
Five Swedish work templates, Swedish start guide, and English user guide in editable DOCX and searchable PDF, as well as a Swedish Excel register. PDF is intended for printing and reading, not interactive filling. Unzip the ZIP before use. Word and a compatible spreadsheet program are required for editing.